The Fulleon RoLP Solista and RoLP Solista Maxi use the same low current technology that made the RoLP (Roshni Low Profile) sounder a global hit and pairs it with a LED visual alarm to create a sounder beacon combination.
As the use of beacons to supplement audible alarms is becoming increasingly common. A combined sounder beacon allows both an audible and visual alarm to be provided through only a single installation point reducing installation time and as such cost.
Two versions are available the RoLP Solista and RoLP Solista Maxi. The RoLP Solista Maxi offers a higher output sounder output than the standard version with six key tones boosted to 105dB(A) delivering a powerful fire alarm sounder beacon that is CPD compliant, compact and a perfect match for the standard RoLP sounder.
Requiring current consumption as low as 30mA, the RoLP Solista, drawing on RoLP sounder technology, is a leader in efficiency, its wide range of selectable tones makes it a signalling leader in conventional fire system sounders.
With 32 tones to choose from (6 fire approved) it's easy to adapt the sounder so that it's fit for purpose in terms of both fire notification and general signalling options.
From commercial premises to off-shore oil platforms, an acoustic alert is typically the primary method of alarm.
Eaton has a library of over 100 industry-standard alerting tones to ensure that your notification is heard every time. Voice alert messages are available in multiple languages for fire evacuation, security or safety.
Designed for adaptability, the RoLP Solista and RoLP Solista Maxi offer you ample choice to meet your projects' needs.
With six different bases available to suit a range of conduit entries. It offers a variety of ingress protection and aesthetic options to suit the installation.
Midi angle single base
Flexi-fit option to facilitate installation in corners, or where the use of grommets or gaskets is preferred.
Deep base
Suitable for all types of surface wiring with an IP65 ingress protection rating, and knockouts for cable entry.
Midi U single base
Easy-fit option to facilitate installation in corners, or where the use of grommets or gaskets is preferred.
Shallow base
Suitable for concealing wiring allowing for installation with minimal visual impact where aesthetics are important.
U-base
Suitable for all types of surface wiring and rated to IP65 ingress protection, with knockouts for cable entry.
Combi signalling unit
An audible and visual signalling system where different levels of warning or status need to be communicated.
*(IHS Markit, 2018).
RoLP Solista, Red Body, Red Led Beacon, Shallow Base ROLPSB/SV/RL/R/S | 8210112FULL-0015X |
RoLP Solista, Red Body, Red Led Beacon, Deep Base ROLPSB/SV/SB/RL/R/D | 8210113FULL-0016X |
RoLP Solista, White Body, Red Led Beacon, Shallow Base ROLPSB/SV/RL/W/S | 8210114FULL-0017X |
RoLP Solista, White Body, Red Led Beacon, Deep Base ROLPSB/RL/W/D | 8210115FULL-0018X |
RoLP Solista, Red Body, Red Led Beacon, No Base ROLPSB/SV/RL/R/N | 8210111FULL-0004X |
RoLP Solista Maxi, Red Body, Red LED Beacon, Shallow Base ROLPX/SB/RL/R/S | 8210119FULL-0001 |
RoLP Solista Maxi, Red Body, Red LED Beacon, Deep Base ROLPX/SB/RL/R/D | 8210130FULL-0002 |
RoLP Solista Maxi, Red Body, Red LED Beacon, U Base ROLPX/SB/RL/R/U | 8210121FULL-0003 |
Voltage: | 9-15Vdc 18-28Vdc 110-230Vac with Powered Base |
Current: | RoLP Solista - 15mA (Typical Tone 3) RoLP Solista Maxi - 43mA (Typical Tone 3) |
Sound Output: | RoLP Solista - 102dB(A) (Typical tone 3) RoLP Solista Maxi - 106dB(A) (Typical Tone 3) |
Tones: | 32 |
Light Output: | > 0.5cd |
Monitoring: | Reverse Polarity |
Temperature: | -10°C to +55°C, |
Protection: | IP54 Shallow Base IP65 Deep & U Base |
Construction: | ABS PC Lens |
Weight: | 0.3Kg |
Colour: | Red & White |
Volume Control: | 10dB |
Flash Rate: | 1Hz |
Flash Colour: | Red |
Light Source: | LED |