Download document () of 20
Backup Power (UPS)

Eaton 93T UPS

The Eaton 93T UPS is a three phase online UPS, with power ratings from 15 – 200 kVA. The UPS is available in a tower form factor and is compatible with Lithium-ion UPS batteries, which are 40 percent smaller than VRLA batteries and have twice the lifespan, saving money on battery replacement costs and extra square footage for battery cabinets. This UPS comes with Unity power factor (VA=W) 1.0

 

Key technologies: Eaton Hot Sync®ABM battery managementEaton’s Energy Saver System (ESS)

Applications: Suitable for commercial buildingsmedium to larger enterprise data centers. For safety, energy efficiency and a low-carbon future

Compliance with standards: CE, RoHS

Brochure: Download 93T UPS brochure

 

TOPOLOGY
Online
POWER RATING RANGE
15 kVA - 200 kVA
FORM FACTOR
Tower

Core features

High availability and easy-to-maintain UPS creates a reliable power protection system for IT installations and mission critical application

  • Real-time monitoring of the capacitor’s status eliminates potential safety issues due to high operating temperature from capacitors
  • Increase battery life by more than 50% with Eaton ABM intelligent battery management technology
  • Module-level maintenance enables low MTTR (mean time to repair)

 

Flexibly adapt to business development, energy storage system upgrades, and IT environment dynamics

  • The built-in Eaton Hot-sync parallel function provides parallel capability for redundancy and capacity upgrades with easy software configuration
  • Charging power up to 70% of UPS’s rated power, compatible with bigger battery capacity and lithium-ion battery system
  • Internal battery compatibility is available for UPS up to 80kVA with 5 mins backup time under full load condition.

 

Optimizing customer initial investment cost and operating costs of the whole lifecycle via cost-effective and high-efficient power supply solution 

  • By adopting three-level topology and industry-leading high-efficient technology, efficiency under double-conversion mode can be maintained above 96% under typical load rates, improving energy utilization. 
  • Achieve up to 99% efficiency in ESS mode as well as under parallel configuration, ensuring higher system availability while maintaining the provision of reliable and quality power
  • Unity output power factor achieved with 100% utilization rate of system capacity
  • Smart load allocation feature enables parallel system to operate at optimized load point
Specifications

EATON 93T UPS TECHNICAL SPECIFICATION

model tab table
model tab table
model tab table
Download Links