PDI WaveStar Monitoring System provides you with the most advanced power distribution equipment monitoring and metering solution to help you make prompt and informed decisions to support fault detection, energy management and tenant billing applications.
PDI WaveStar is designed for real-time sensing, measuring, collecting, calculating, reporting and alarming of all electrical and equipment performance metrics.
PDI WaveStar ensures that you have metering data at the level of precision you need to accurately monitor consumption and validate your results.
PDI WaveStar comes standard with both local and remote access to your equipment monitoring and metering solution making it easier than ever to visualize, navigate, manage and configure your power distribution equipment monitoring.
PDI WaveStar supports a variety of optional monitoring and metering features both today and well into the future.
The combination of multiple physical connection options, high data transfer rates and standard protocol support makes communication and integration with PDI WaveStar easy and versatile.
Contact us to learn more about the PDI WaveStar Monitoring System.
Ratings | |
General | Operating temperature: 0°C to 60°C (32°F to 140°F) Storage temperature: -40°C to 70°C (-40°F to 158°F) <95% Relative humidity, non-condensing Control power 90 to 500 Vac (line-to-line) Resolution of 24-bit per channel Frequency range of 50 Hz or 60 Hz Sample rate of 7680 Hz per channel Maximum data refresh rate of 1 second |
Display | 7-inch color touchscreen Capacitive touch technology 800×480 resolution Audio speaker |
Network intergration | Ethernet RJ-45 Serial RS-485 (4-wire & 2-wire) Serial baud rate support 9.6k to 115.2k (configurable) Native Modbus RTU Native Modbus TCP SNMP (Version 1 & Version 2) Native TCP/IP WebServer (HTML 5 Support) |
Panel board monitoring | Mains monitoring: CT ratings of 100A to 3200A Voltage range of 208V (L-L) to 480V (L-L) Measured values: Frequency Voltage (L-L & L-N) Current (per phase, neutral & ground) Real power (per phase & sum) Apparent power (per phase & sum) Energy (per phase & sum) Power factor (signed) Branch Circuit Monitoring: Maximum CT rating of 100A Measured values Current (demand & peak) Power (real, apparent) Energy (kWh) Power factor (signed) |
Sub-feed monitoring | CT ratings of 100A to 3200A Measured values: Current demand (per phase, neutral & ground) Current peak (per phase, neutral & ground) Real power (per phase & sum) Apparent power (per phase & sum) Reactive power (per phase & sum) Energy (per phase & sum) Power factor (signed) |
Transformer monitoring | Voltage range support of 208V (L-L) to 600V (L-L) Transformer configuration support: Delta-Delta (Δ- Δ) Delta-Wye (Δ-Y) Wye-Wye (Y- Y) Delta (Δ) -ZigZag Wye (Y) -ZigZag Support for local & remote emergency power off (EPO) Measured values: Voltage (L-L & L-N) Frequency Current demand (per phase, neutral & ground) Current peak (per phase, neutral & ground) Real power (per phase & sum) Apparent power (Per phase & sum) Reactive power (Per phase & sum) Energy (per phase & sum) Power factor (signed) Transformer Temperature(normal/elevated/alarm) |