Low-voltage switchgear

Front-access Magnum PXR low-voltage switchgear

Front-access Magnum PXR low-voltage switchgear combines the robustness of UL 1558/CSA C22.2 No. 31 low-voltage switchgear with the flexibility of switchboard design. Front-access switchgear can be mounted against a wall, corner or in other tight locations where standard, rear-access switchgear line-up would not normally fit. Front-access switchgear is available with the same Magnum circuit breakers with Power Xpert Release trip units as rear-access switchgear. 

VOLTAGE CLASS
Up to 600 V
CONTINUOUS CURRENT
Up to 6,000 A
SHORT-CIRCUIT RESISTANT
100 kA

Core features

  • Front-access cable compartment 18, 22, 30 or 44 inches wide
  • Draw-out LV power circuit breakers with 100% rated, fully selective protection and integral microprocessor-based circuit breaker tripping systems
  • Engineered-to-order configurations available to accommodate a wide range of applications
  • Complies with UL 1558 and CSA C22.2 No. 31 safety standards
  • Standard 40.2-inch switchgear depth
  • Breaker arrangement up to four high
  • Silver-plated copper bus standard, tin-plated optional
  • NEMA 1 indoor and NEMA 3R outdoor aisle and aisleless enclosures available

Monitor and analyse

Power Xpert Dashboard allows users to monitor their switchgear through one-line diagrams, keep tabs on energy usage and even monitor, diagnose and control devices – all while being away from the switchgear itself.
power-xpert-dashboard-crop.jpg

Flexibility with enhanced safety

Now you can combine the flexibility of front-access switchgear with the safety of C37.20.7 arc-resistant switchgear.

Automatic transfer schemes

When providing redundant power sources for critical power applications, select the:

  • Eaton ATC-900 controller for line-ups with main-main, main-generator or generator-generator applications
  •  Eaton PLC with Eaton touchscreen for automatic main-tie-main transfer
  • Eaton Power Xpert Dashboard to monitor or control transfer schemes for a main-tie-main and adjust settings and sequence details
Specifications

Ratings

VOLTAGE
Up to 600 V
CONTINUOUS MAIN BUS CURRENT 1,600 A to 6,000 A
SHORT-CIRCUIT RESISTANT Up to 100 kA
SHORT-TIME RESISTANCE 30 cycles
CIRCUIT BREAKER AMPS Up to 6,000 A

Standards

ANSI/IEEE C37.20.1, C37.51
UL
1558 and 1066
CSA
C22.2 No. 31 and No. 268
OTHER CERTIFICATION ABS
SEISMIC QUALIFICATION

Contact factory

 

Enclosure

CONSTRUCTION
Metal-enclosed
POWER TERMINATIONS Front access
INSULATING MEDIUM Air
ENCLOSURE TYPE NEMA 1 indoor, NEMA 3R outdoor
INDOOR SECTION DIMENSIONS 18–44” w x 40.2” d x 96” h

Devices

OVERCURRENT PROTECTION Power circuit breaker, UL 1066 and CSA C22.2 No. 268
DEVICE MOUNTING Drawout
Download Links