The explosion-protected escape and exit sign luminaire is approved for areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 21 and 22, according to the APEX 94/9/EG directive. With the high IP66 protection and robust housing, it is ideal for use in industrial environments.
Order code | Description |
GHG8712001R0001 | dKLK 23 V-CG-S with eXLink, Luminaire with CG monitoring and 20-digit address switch, without light source, with eXLink |
GHG8712001R0101 | dKLK 23 V-CG-S with Ex d screw, Luminaire with CG monitoring and 20-digit address switch, without light source, with pressure-resistant cable entry |
Order code | Description |
GHG 8701914 R0005 | Lamp, LLED 8G 6027 LmKW 8W SPP1 (640 lm) |
Marking acc. to RL 2014/34/EU: | II 2G Ex d IIC T6 Gb II 2D Ex tb IIIC T80°C Db IP66 |
EU-type inspection certificate: | BVS 10 ATEX E003 |
Housing Material: | glass-fibre reinforced polyester |
Protective cover: | Polycarbonate (850 °C glow wire resistant) |
Rated voltage: | AC: 230 V +/– 10 %, 50-60 Hz DC: 220 V + 25 %/– 20 % |
Rated current: | ca. 76 mA |
Permissible ambient temperature: | –20 °C to +45 °C (depends on lamp wattage and mounting position) |
Power connection: | pressure-resistant connector plug eXLink, 3pole Ex d cable entry M20 x 1.5 for cables Ø 7-12 mm |
Coupler (enclosed) (type: exLink): | 2 + PE cage clamp terminal for power Ø 8-11 mm and max. 1.5 mm2 (rigid) |
Connection terminals (Ex-d-Verschluss): | L, N, PE, max. 2.5 mm2 terminals |
Light source: | LLED 8G 6027 LmKW 8W SPP1 (640 lm) |
Weight: | approx. 1.7 kg |