Download document () of 20
Systems

LoadStar-PS - AC/AC Central Battery System

LoadStar-PS is the new family of emergency lighting AC/AC central battery systems.

The LoadStar-PS range is designed specifically for long term sustainability, offering reduced carbon footprint and running costs, without compromising on performance.

Due to the passive standby operation of the inverter, which only operates when required, the running power is kept to a minimum, in turn reducing overall running costs and maximising equipment life.

LoadStar-PS is fully compliant with EN50171, which means that you can rest assured that it can be depended upon if the worst were to happen.

Single and three-phase options
EN50171 compliant
Automatic test system AT-S+

Features

  • High efficiency EN50171 CPS specific for safety applications  
  • 2, 5, 10 and 20 kVA with single and three phase output voltage
  • Intuitive, multilingual 5” touchscreen display
  • Parallel mode up to 6 systems of the same kVA value and phase type
  • Elegant, RAL9005 black matt metallic enclosure for both units and batteries  
  • Specific I/O, as required from EN50171, for failure reporting and test system integration 
  • Extended battery life thanks to the Advanced Battery Management (ABM) charge routine
  • Compatible with Eaton AT-S+ emergency lighting monitoring system

No limitations on system design and perfect integration with general lighting luminaires.

Together with a range of field devices, which include the Hold Off Relay (HOR), Change Over Relay (COR) and Sub-circuit Monitor (SCM), available as field accessories, LoadStar-PS can operate in Maintained, Non-Maintained and Switched Maintained mode offering a perfect integration with general lighting luminaires.

LoadStar-PS provides a constant “Maintained” power to EL distribution boards, then based on the system design, it is possible to select from three different operating modes:

  • Maintained: luminaires are always ON, this type of operation is mainly used for Exit Signs. They remain ON in case of mains failure.
  • Non-Maintained: luminaires are always OFF, typically used with dedicated emergency lighting fittings. They switch ON in case of mains failure.
  • Switched Maintained: luminaires can be switched ON/OFF, typically used with general lighting luminaires. They switch ON in case of mains failure.
LoadStar-PS Schematic

Intuitive HMI and status LEDs

LoadStar-PS units come with a modern and intuitive 5” touchscreen display. All settings and parameters can be easily set up via password protected HMI.

For user safety and convenience, the units feature a range of coloured LED indicators which are clearly visible even from a distance. This enables users to immediately understand the system status, without having to operate the display.

LoadStar-PS - Green LEDs
LoadStar-PS - Yellow LEDs
LoadStar-PS - Red LEDs

Service friendly design

Due to its factory modular designs, LoadStar-PS simplifies routine maintenance procedures and servicing.

Power modules can be replaced or added while other modules continue protecting the load

Replacement and upgrade operations typically take less than 10 minutes, resulting in a reduced mean time to repair (MTTR).

Service maintenance picture
Specifications
Highlight differences
Show only differences
Hide blank features

PRODUCT CODES

Luminaires

Order code Description
Systems
LSPS1P2KB0 LoadStar-PS 2KVA 1ph
LSPS1P5KB0 LoadStar-PS 5KVA 1ph
LSPS3P10KB0 LoadStar-PS 10KVA 3ph
LSPS3P10KB1 LoadStar-PS 10KVA 3ph
LSPS3P10KB2 LoadStar-PS 10KVA 3ph
LSPS3P20KB0 LoadStar-PS 20KVA 3ph
LSPS3P20KB3 LoadStar-PS 20KVA 3ph
LSPS3P20KB4 LoadStar-PS 20KVA 3ph
Internal batteries
P-103003010-002 Kit Internal battery string (32x9AH LL)
External battery cabinets
P-105000111-002 Battery Sidecar 1x32 9AHLL
P-105000041-006 EBC-A-2x32-9AHLL-BB-63A
P-105000041-007 EBC-A-3x32-9AHLL-BB-63A
P-105000084-002 EBC-B-1x32-CSBHRL12200W-BB-63A-M6
P-105000017-004 EBC-C-1x36-CSBHRL12200W-BB-200A-M6
P-105000017-010 EBC-C-1x40-CSBHRL12200W-BB-200A-M6

TECHNICAL SPECIFICATIONS

Input / Output wiring:

2 / 5 kVA 1 Phase + N + PE

10 / 20 kVA 3 Phases + N + PE

Input frequency range: 40 to 72 Hz
Housing: Metallic enclosure with RAL9005 black matt coating
Protection degree (Units): IP20 (IP21 kit available as accessory)
Working temperatures:

Max allowed ambient temperature range +0 to +40°C

Recommended temperature range +20 to +25°C

(for battery 10Y lifetime)

Altitude: 1000 m without derating (max 2000 m)
Battery type: VRLA / AGM 10 year design lifetime
I/O free potential contacts:

Input: mains cut simulation (force battery mode), EPO (emergency power OFF)

Output: general failure, battery mode active, battery deep discharge active