CEAG GHG51 IEC 60309 Hazardous Area Stainless Steel Enclosed Receptacles

Crouse-Hinds series CEAG GHG51 IEC 60309 stainless steel receptacles have been carefully engineered to offer reliability, efficiency and added safety protection in Zones 1, 2, 21 and 22, as well as in demanding wet locations, particularly where harsh wash downs are a must.

Constructed from 316L stainless steel, 16A through 125A IEC 60309 receptacles are robust, durable and corrosion-resistant.

Additionally, there is ample room inside the enclosure for simplified installation using Ex-e connecting terminals.

Certifications and compliances

16A

  • Marking accd. to 94/9/EC: Ex II 2 G Ex de IIC T6; Ex II D Ex tD A21 IP66 T80°C
  • EC-Type Examination Certificate: PTB 99 ATEX 1039
  • IECEx Certificate of Conformity: IECEx BVS 12.0027
  • Marking accd. to IECEx: Ex de mb IIC T5/T6 Gb; Ex tb IIIC T80°C Db IP66
  • Permissible ambient temperature: -20°C to +40°C
  • Protection class: I
  • Degree of protection accd. to EN 60529: IP66

32A

  • Marking accd. to 94/9/EC: Ex II 2 G Ex de IIC T6; Ex II D Ex tD A21 IP66 T80°C
  • EC-Type Examination Certificate: PTB 99 ATEX 1041
  • IECEx Certificate of Conformity: IECEx BVS 12.0027
  • Marking accd. to IECEx: Ex de mb IIC T5/T6 Gb; Ex tb IIIC T80°C Db IP66
  • Permissible ambient temperature: -20°C to +40°C
  • Protection class: I
  • Degree of protection accd. to EN 60529: IP66

63A

  • Marking accd. to 94/9/EC: Ex II 2 G Ex de IIC T6; Ex II D Ex tD A21 IP66 T80°C
  • EC-Type Examination Certificate: PTB 00 ATEX 1070
  • IECEx Certificate of Conformity: IECEx BVS 12.0027
  • Marking accd. to IECEx: Ex de mb IIC T5/T6 Gb; Ex tb IIIC T80°C Db IP66
  • Permissible ambient temperature: -20°C to +40°C*
  • Protection class: I
  • Degree of protection accd. to EN 60529: IP66

125A

  • Marking accd. to 94/9/EC: Ex II 2 G Ex de IIC T6; Ex II D Ex tD A21 IP66 T80°C
  • EC-Type Examination Certificate: PTB 01 ATEX 1069
  • IECEx Certificate of Conformity: IECEx BVS 12.0027
  • Marking accd. to IECEx: Ex de mb IIC T5/T6 Gb; Ex tb IIIC T80°C Db IP66
  • Permissible ambient temperature: -20°C to +40°C*
  • Protection class: I
  • Degree of protection accd. to EN 60529: IP66

*Extended temperature range available upon request.

GHG51 models

  • 16A receptacle = GHG511
  • 32A receptacle = GHG512
  • 63A receptacle = GHG514
  • 125A receptacle = GHG515

Design features

  • Robust & durable enclosure made of AISI 316L stainless steel
  • Increased resistance against chemicals, salt water and higher impact conditions
  • Easy to clean design
  • High ingress protection (IP66) applies also in the plugged-in state
  • Full AC-3 switching ability
  • Compatible with existing and proven GHG 51 plugs
  • Easy looping options without using of junction boxes (16A-125A)
  • External earth bolt to connect ground
  • Panel mounting possibilities

Standard materials

  • Enclosure – 316L stainless steel
Especificaciones

Ordering information

Catalog number Product description
GHG5114304R1001 Ex-wall socket 1: 16A, 110-130V / 3-pole / stainless steel housing
GHG5114306R1001 Ex-wall socket 1: 16A, 200-250V / 3-pole / stainless steel housing
GHG5114405R1001 Ex-wall socket 1: 16A, 690V / 4-pole / stainless steel housing
GHG5114406R1001 Ex-wall socket 1: 16A, 690V / 4-pole / stainless steel housing
GHG5114506R1001 Ex-wall socket 1: 16A, 200-250V / 380-415V / 5-pole / stainless steel housing
GHG5124405R1001 Ex-wall socket 1: 32A, 690V / 4-pole / stainless steel housing
GHG5124406R1001 Ex-wall socket 1: 32A, 690V / 4-pole / stainless steel housing
GHG5124407R1001 Ex-wall socket 1: 32A, 690V / 4-pole / stainless steel housing
GHG5124409R1001 Ex-wall socket 1: 32A, 690V / 4-pole / stainless steel housing
GHG5124506R1001 Ex-wall socket 1: 32A, 200-250V / 380-415V / 5-pole / stainless steel housing
GHG5144405R1001 Ex-wall socket 1: 63A, 690V / 4-pole / stainless steel housing
GHG5144406R1001 Ex-wall socket 1: 63A, 690V / 4-pole / stainless steel housing
GHG5144407R1001 Ex-wall socket 1: 63A, 690V / 4-pole / stainless steel housing
GHG5144506R1001 Ex-wall socket 1: 63A, 200-250V / 380-415V / 5-pole / stainless steel housing
GHG5154405R1001 Ex-wall socket 1: 125A, 690V / 4-pole / stainless steel housing
GHG5154406R1001 Ex-wall socket 1: 125A, 690V / 4-pole / stainless steel housing
GHG5154407R1001 Ex-wall socket 1: 125A, 690V / 4-pole / stainless steel housing
GHG5154506R1001 Ex-wall socket 1: 125A, 200-250V / 380-415V / 5-pole / stainless steel housing

 