LoadStar-PS is the new family of emergency lighting AC/AC central battery systems.
The LoadStar-PS range is designed specifically for long term sustainability, offering reduced carbon footprint and running costs, without compromising on performance.
Due to the passive standby operation of the inverter, which only operates when required, the running power is kept to a minimum, in turn reducing overall running costs and maximising equipment life.
LoadStar-PS is fully compliant with EN50171, which means that you can rest assured that it can be depended upon if the worst were to happen.
Features
No limitations on system design and perfect integration with general lighting luminaires.
Together with a range of field devices, which include the Hold Off Relay (HOR), Change Over Relay (COR) and Sub-circuit Monitor (SCM), available as field accessories, LoadStar-PS can operate in Maintained, Non-Maintained and Switched Maintained mode offering a perfect integration with general lighting luminaires.
LoadStar-PS provides a constant “Maintained” power to EL distribution boards, then based on the system design, it is possible to select from three different operating modes:
Intuitive HMI and status LEDs
LoadStar-PS units come with a modern and intuitive 5” touchscreen display. All settings and parameters can be easily set up via password protected HMI.
For user safety and convenience, the units feature a range of coloured LED indicators which are clearly visible even from a distance. This enables users to immediately understand the system status, without having to operate the display.
Service friendly design
Due to its factory modular designs, LoadStar-PS simplifies routine maintenance procedures and servicing.
Power modules can be replaced or added while other modules continue protecting the load.
Replacement and upgrade operations typically take less than 10 minutes, resulting in a reduced mean time to repair (MTTR).
Your search "" did not match any documents or products.
Order code | Description |
Systems | |
LSPS1P2KB0 | LoadStar-PS 2KVA 1ph |
LSPS1P5KB0 | LoadStar-PS 5KVA 1ph |
LSPS3P10KB0 | LoadStar-PS 10KVA 3ph |
LSPS3P10KB1 | LoadStar-PS 10KVA 3ph |
LSPS3P10KB2 | LoadStar-PS 10KVA 3ph |
LSPS3P20KB0 | LoadStar-PS 20KVA 3ph |
LSPS3P20KB3 | LoadStar-PS 20KVA 3ph |
LSPS3P20KB4 | LoadStar-PS 20KVA 3ph |
Internal batteries | |
P-103003010-002 | Kit Internal battery string (32x9AH LL) |
External battery cabinets | |
P-105000111-002 | Battery Sidecar 1x32 9AHLL |
P-105000041-006 | EBC-A-2x32-9AHLL-BB-63A |
P-105000041-007 | EBC-A-3x32-9AHLL-BB-63A |
P-105000084-002 | EBC-B-1x32-CSBHRL12200W-BB-63A-M6 |
P-105000017-004 | EBC-C-1x36-CSBHRL12200W-BB-200A-M6 |
P-105000017-010 | EBC-C-1x40-CSBHRL12200W-BB-200A-M6 |
Input / Output wiring: | 2 / 5 kVA 1 Phase + N + PE 10 / 20 kVA 3 Phases + N + PE |
Input frequency range: | 40 to 72 Hz |
Housing: | Metallic enclosure with RAL9005 black matt coating |
Protection degree (Units): | IP20 (IP21 kit available as accessory) |
Working temperatures: | Max allowed ambient temperature range +0 to +40°C Recommended temperature range +20 to +25°C (for battery 10Y lifetime) |
Altitude: | 1000 m without derating (max 2000 m) |
Battery type: | VRLA / AGM 10 year design lifetime |
I/O free potential contacts: | Input: mains cut simulation (force battery mode), EPO (emergency power OFF) Output: general failure, battery mode active, battery deep discharge active |
Support from Eaton
Need product support?
Phone: 01753 608 700, option 3 then option 3