Download document () of 20
Security & intruder alarm systems

i-on1000EX - Large commercial hybrid intruder panel

The Multibus has 10 bus lines and supports up to 250 bus devices giving 100 zones per bus, scaling up to 1000 expandable zones. With ten zones per expander instead of the traditional 8 identification of zones is easier with the expander. Installers can fit up to 250 bus devices such as keypads and expanders on the Multibus panel allowing far greater and more flexible expansion than any other panel on the market. Semi-automatic device addressing prevents address duplication of bus device address, saving hours of installation diagnostic time. Bus device locator enables any bus device to be located quickly and easily by the installer. Suitable for use in commercial environments such as hospitals, universities, schools, shopping centres and large commercial properties.
Expandable
Expandable to 1000 fully programmable zones
Certification
EN50131 Grade 2 and 3
Up to 1000 users
With a code, prox-tag and a hold up device (HUD)

Simple to service

Audible bus device locating - locate any bus device quickly and easily, therefore reducing the time taken to complete maintenance and service calls.

Scalability

The multibus supports up to 250 bus devices scaling up to 1000 expandable zones. This scalability makes it the perfect panel for a variety of large installations from universities to warehouses.

Technology you can rely on

Quality, reliability and resilience are designed into Eaton’s Scantronic products at the outset. With thousands of panels already installed in a variety of environments, be confident in your panel wherever the job.

WebBrowser configuration

Eaton’s web-based configuration allows the installer to configure the i-on1000EX from anywhere on the local network using any web-enabled device. This considerably speeds up the programming and allows the profile to be easily backed up.

Flexibility

The panel can be set-up wired or wirelessly. It can also be configured using Eaton Downloader via USB IP or plug-on comms module, web browser via built in Ethernet port. More options give installers more control.

The i-on1000 panels are compatible with Eaton's full range of keypads

Across the range, there are a number of finishes and installation solutions to suit the desired system and building.

Specifications
Highlight differences
Show only differences
Hide blank features

Technical Specifications

Compliance: PD6662:2017, EN50131-1:2006 and A1:2009 Grade 2 or 3 and environmental class 2
EN50131-3:2009, EN50131-6:2008, BS8243:2010
Zones: Expandable to 1000 fully programmable zones
Users: Up to 1000 users with 4 or 6 digit user codes, with the option for each user to add a proximity tag,
radio remote control* and radio panic (HUA) button*
Power and Battery: 3Amps, conforms to EN50131-6 Type A power supply, rated power output 1.1Amps whilst charging
two 17Ah batteries
Battery Accepts two 12v standby batteries up to 17Ah rechargeable lead acid, gel type. Independently
charged and monitored
Log Events: 6500 events; 5000 mandatory events and 1500 non-mandatory events
Bus: 10 dependent buses (5 when paired)
Bus devices: Accepts up to 250 (25 per bus, 50 when paired) bus devices (of which 1 must be a keypad)
Partitions / Wards: 50 independent Partitions/Wards
Dimensions: Panel 320 x 400 x 98, mm (H x W x D)       
Download Links

Looking for a manual?

Professional alarm installers can download engineering and installation guides for the Eaton i-on1000EX intruder alarm control panel by signing into our MyScantronic installer hub.

Need product support?

Support from Eaton

Need product support?

9am - 5pm, Monday to Friday.

Phone: 01753 608700 option 3, then option 5