Download document () of 20
Eaton switch & control gear enclosure

Glasgow Fuse Switch-Disconnectors

For many years, the Glasgow product name has been synonymous with quality, trust and reliability and as part of our long-standing commitment to its tried and tested design we’ve reinvested for the future by re-tooling the whole range and introducing a more flexible solution for our customers. 

The Glasgow range is now ordered as a modular solution, whereby the enclosure and fuselinks or switchlinks are ordered separately. This allows for installation flexibility by pairing the required fuselink or switchlink with the necessary enclosure. 

Glasgow fuse switch disconnectors and switch disconnectors meet the constructional requirements for isolation of and are type tested to BS EN 60947-3. Conditional short circuit current rating tests at a value of 80kA rms Ue 415V have been carried out with Eaton HRC fuses fitted. Please see the product matrix for right Glasgow enclosure and matching fuselink and/or switchlink.

Core features

  • Meet the constructional requirements for isolation of and are type tested to BS EN 60947-3
  • Units can be fitted with HRC fuselinks of maximum rating but will accept fuselinks of a lower rating. 
  • SPSN and TPSN indicate switched neutral 
  • Neutral makes first break and last 
  • If DP fuse-switch-disconnectors are required, use SPSN and replace the solid link with an additional fuselink

Enclosures

Surface-mounting enclosures comprise heavy gauge steel body plates incorporating cast iron frame members and are rustprotected, with a light grey paint finish (RAL7004). Front access doors, which are detachable, are fitted with dust-excluding gaskets and are interlocked to prevent opening when the switch is ‘on’. The interlock can be defeated by a competent person for maintenance purposes. Operating handles may be locked in both the ‘on’ and ‘off’ positions. Castell type interlocks can be supplied to special order. Internal fixing holes allow units to be mounted closely side by side and all models have removable top and bottom end plates. These are pierced for connections, divided into front and rear (fixed) portions to simplify cabling using Eaton’s MEM series split-type cable boxes, and provided with undrilled cover plates.

Fuses

Glasgow units are designed for use with HRC cartridge fuse links to BS88: Part 2. 63A and 100A units employ off-set contact fuse links. All performance tests have been carried out using Eaton BS88 fuselinks.

Motor ratings

The motor ratings assigned to TPN switch-disconnector units are utilisation category AC23A (frequent operation) to BS EN 60947-3, which calls for make and break testing at 10 and 8 times rated current respectively for units having a motor rating up to and including 100 Amps. Ratings for switch-disconnector-fuses are dependent on suitable HRC fuses being fitted.

Auxiliary equipment

A comprehensive range of extension boxes and spreader boxes is available. Units can be fitted with HRC Fuselinks of maximum rating but will accept fuselinks of a lower rating, refer to the Paramount HRC Fuselinks page. SPSN and TPSN indicate switched neutral. Neutral makes first and breaks last. If DP fuse-switch-disconnectors are required, use SPSN and replace the solid link with an additional  fuselink.

Definitions of utilisation category:

  • AC20a – Connecting and disconnecting under no load condition.
  • AC21a – Switching of resistive loads including moderate overloads.
  • AC22a – Switching of mixed resistive and inductive loads including moderate overloads.
  • AC23a – Switching of motor, or other high inductive loads.

Cable extension boxes

Fabricated sheet steel boxes boxes can be fitted top/bottom of Glasgow switch units to provide additional space for spreading multi-core PVC insulated cables with solid aluminium conductors and for some larger cables with stranded copper conductors. For 1–3PCB, a plain flame retardant plywood plate is provided for fitting between the box and switch unit, the steel endplate supplied fitted to the switch unit being used on the box’s cable entry side. For 4PCB, a plain steel plate is provided for cable entry on box. The switch enclosure has 8mm thick insulated endplates fitted both ends. For 5–6PCB, a 10mm thick insulated plate is provided for cable entry on box. The switch enclosure has 10mm thick insulated endplates fitted both ends, 5PCB includes a flame-retardant plywood packer for fitting between PCB and switch unit’s endplate to provide lid flange clearance.

Specifications

The Glasgow range is now ordered as a modular solution, whereby the fuselinks or switchlinks are ordered separately.

Note: Failure to fit the designed Eaton Switchlinks or Fuselinks will invalidate the warranty on the product

 

Switchlinks

Enclosures

Eaton Switchlinks

61GN, 63GN, 64G

63 MLK

101GN, 103GN, 104G

100 MLK

203GN, 204G

200 MLK

403GN, 404G

400 MLK

603GN

630MLK

803GN

800MLK

Fuselinks

Enclosures

Eaton Fuselinks

61GN, 63GN, 64G

BAO63

101GN, 103GN, 104G

CEO100

203GN, 204G

DD200

403GN, 404G

ED400

603GN

FF630

803GN

GF800

Units can be fitted with HRC Fuselinks of maximum rating but will accept fuselinks of a lower rating, refer to the Paramount HRC Fuselinks page for the full range.

Please see the product matrix below that will help you to select the Glasgow enclosure and match it with the right fuselinks and/or switchlinks.

Download Links

Need product support?

Support from Eaton

Need product technical support?

Phone: +44 (0) 1753 608 700, Option 3 then Option 1