This product has been discontinued and is no longer available. For technical support contact FireTechSupport@Eaton.com.
The JSB range of BiWire control panels are designed with patented 2 wire technology (Patent Number GB2293257) and also includes patented ‘Self-Check’ detector features (Patent Number EP:02253889).
BiWire conventional detectors, sounders, LED beacons, and relay modules, all share the same zone wiring, delivering significant savings in both cable and installation costs.
All panels in this range have the facility to flash detector LED’s in a zone to facilitate the location of any wiring fault in that zone, thereby simplifying the fault finding process.
JSB BiWire 2 Zone Panel | FX2202BW |
JSB BiWire 4 Zone Panel | FX2204BWHMO |
JSB BiWire 8 Zone Panel | FX2208BWHMO |
Code | FX2202BW | FX2204BWHMO | FX2208BWHMO |
Description |
2 zone Bi-Wire panel |
4 zone Bi-Wire panel |
8 zone Bi-Wire panel |
Standards |
EN54 Pt2 & Pt4 EN50130-4: 1996 EN500081-1: 1992, EN61000-2-2: 1994 |
EN54 Pt2 & Pt4 EN50130-4: 1996 EN500081-1: 1992, EN61000-2-2: 1994 |
EN54 Pt2 & Pt4 EN50130-4: 1996 EN500081-1: 1992, EN61000-2-2: 1994 |
Specification |
|||
Number of Zones |
2 |
4 |
8 |
Detectors per Zone |
20 |
20 |
20 |
Sounders per Zone |
20 |
20 |
20 |
Alarm Circuit Load per Zone |
150mA |
150mA |
150mA |
End of Line Devices |
Active end of line monitoring unit |
Active end of line monitoring unit |
Active end of line monitoring unit |
Auxiliary Fire Signal/Fault Output |
1A 24V dc single pole changeover contacts |
1A 24V dc single pole changeover contacts |
1A 24V dc single pole changeover contacts |
HMO Facility |
NO |
Yes (on all zones) |
Yes (on all zones) |
Mains Input Voltage |
230V ac –10% +15% |
230V ac –10% +15% |
230V ac –10% +15% |
Operating Voltage |
24V dc |
24V dc |
24V dc |
Standby Duration |
24 hours |
24 hours |
24 hours |
Battery |
1 x 2.1Ah (sealed lead acid) |
1 x 3.2Ah (sealed lead acid) |
2 x 3.2Ah (sealed lead acid) |
Recharge Period |
24 hours |
24 hours |
24 hours |
Environmental |
|||
Operating Temperature |
-5°C to +40°C |
-5°C to +40°C |
-5°C to +40°C |
Humidity (non condensing) |
0 to 75% RH |
0 to 75% RH |
0 to 75% RH |
Physical |
|||
Construction |
PC |
PC |
PC |
Dimensions |
260mm x 212mm x 72mm |
332mm x 270mm x 92mm |
332mm x 270mm x 92mm |
Weight |
5.2kg |
5.8kg |
6.0kg |
Ingress Protection |
IP30 |
IP30 |
IP30 |
Cable Entry |
Top: 6 x 20mm entries with blanking plugs, rear cable entry aperture |
Top: 12 x 20mm entries with blanking plugs, rear cable entry aperture |
Top: 12 x 20mm entries with blanking plugs, rear cable entry aperture |
Support from Eaton
Need urgent product technical support?
Phone: +44 (0) 1753 608 700, option 3 then option 4