The BECODISC BXP stacked disc cartridges contain two layers of BECO PR depth filter sheets, which meet the high demands of the pharmaceutical industry, in one filter unit. The double layer design of the filter cells allows a two-step filtration with fine-tuned retention ratings for pre- and fine filtration. The product range covers retention rates between 20 and 0.1 μm, to ensure a comprehensive portfolio for all customer needs.
Segments:
Water throughput at | ||||||
Utilized BECO PR- depth filter sheet | Nominal retention rate μm | Δ p = 100 kPa* in l/m²/min | Δ p = 14.5 psi in gpm/ft² | Endotoxincontent (EU/ml) | Code Pre-filter layer | Code Main filter layer |
PR Steril S 100 | 0.1 | 30 | 0.7 | < 0.125 | A | 01 |
PR Steril S 80 | 0.2 | 46 | 1.1 | < 0.125 | B | 02 |
PR Steril 40 | 0.4 | 61 | 1.5 | < 0.125 | C | 04 |
PR 12 | 0.8 | 175 | 4.3 | < 0.125 | D | 08 |
PR 5 | 2.0 | 330 | 8.1 | < 0.125 | E | 20 |
PR 1 | 4.0 | 2381 | 58.4 | < 0.125 | F | 40 |
PR CP03S | 20.0 | 7140 | 175.2 | < 0.125 | G | [-] |
* 100 kPa = 1 bar ** Endotoxin content analysis after rinsing with 1.23 gal/ft² (50 l/m²) of WFI (Water for Injection) |