Front Access Magnum DS low-voltage switchgear combines the robustness of UL 1558 low voltage switchgear with the flexibility of UL 891 switchboard design. The front-accessible switchgear offering allows mounting against a wall, into a corner, back-to-back, or in other tight locations where a standard rear-accessible switchgear lineup would not normally fit. Front access switchgear is available with the same Magnum DS and NRX circuit breakers as rear-accessible switchgear. 

VOLTAGE CLASS
Up to 600 V
CONTINUOUS CURRENT
Up to 6000 A
SHORT-CIRCUIT WITHSTAND
Up to 200 kA

Core features

  • Front-accessible cable compartment 18, 22, 30 or 44 inches wide
  • Draw-out LV power circuit breakers with 100%-rated, fully selective protection and integral microprocessor-based breaker tripping systems
  • Engineered-to-order configurations available to accommodate a wide range of applications
  • Complies with UL 1558 and UL 891 safety standards
  • Standard 40-inch switchgear depth
  • Up to 4-high breaker arrangement
  • Silver plated copper bus standard, tin plated optional
  • NEMA 1 indoor and NEMA 3R outdoor aisle and aisleless enclosures available

A digital transformation is here

Introducing Magnum PXR switchgear. Our next generation of switchgear builds on the proven capabilities of the Magnum DS platform, now with Power Xpert Release trip units, additional mechanical features and an updated look.
eaton-magnum-pxr-promo-500x250.jpg

 

 

Learn about the MRR1000 Remote Racking device

Automatic transfer schemes

When providing redundant power sources for critical power applications, select the:

  • Eaton ATC-900 controller for lineups with main-main, main-generator or generator-generator applications
  • Eaton PLC with Eaton touchscreen for automatic main-tie-main transfer
  • Eaton Power Xpert Dashboard to monitor or control transfer schemes for a main-tie-main and adjust settings and sequence details

Modernize and extend the life of Magnum DS low-voltage switchgear

Genuine Magnum DS switchgear accessories and replacement parts improve the reliability, safety and longevity of the switchgear.
Specifications

Ratings

VOLTAGE
Up to 600 V
CONTINUOUS MAIN BUS CURRENT 1,600 A to 6,000 A
SHORT-CIRCUIT WITHSTAND Up to 200,000 A
SHORT-TIME WITHSTAND 30 cycles
CIRCUIT BREAKER AMPS Up to 6,000 A

Standards

ANSI / IEEE C37.20.1, C37.51
UL
C22.2 No. 31-10
CSA
C22.2 No. 31-10
OTHER CERTIFICATIONS ABS
SEISMIC QUALIFICATION

IBC, CBC , UBC Zone 4

Front & Rear access

 

 

Enclosure

CONSTRUCTION
Metal-enclosed
POWER TERMINATIONS Front access
INSULATING MEDIUM Air
ENCLOSURE TYPE NEMA 1 indoor, NEMA 3R outdoor
INDOOR SECTION DIMENSIONS 18-44” w x 40” d x 96” h

Devices

OVERCURRENT PROTECTION Power circuit breaker, UL 1066
DEVICE MOUNTING Draw-out