Eaton's Cooper Power series VSA group electronically controlled, three-phase, automatic circuit reclosers with vacuum interrupters, provide reliable and economic overcurrent protection to meet a variety of line and substation applications for 15 kV systems (up to 1200 A continuous/ 20,000 A interrupting current). Recloser operations are programmed on the electronic control panel with accurate, preset tripping characteristics and reclosing times, enabling close coordination with other protective devices on the system. When system requirements change, program settings are easily altered with no sacrifice of accuracy or consistency. Recloser and control accessories enable further tailoring of the protective program to achieve maximum system operating flexibility.
Maximum design voltage (kV) |
15.5 | |
Nominal operating voltage (kV) |
2.4-14.4 |
|
Basic Insulation Level (BIL) (kV) |
110 |
|
60 Hertz withstand voltage (kV) |
Dry, one minute |
50 |
Wet, ten seconds |
45 | |
Continuous current rating (amps) |
VAS12B |
600 |
VSA12, VSA16, VSA20 |
800 | |
VSA20A |
1200 | |
Symmetric interrupting current (amps) |
VSA12, VSA12B |
12000 |
VSA16 |
16000 | |
VSA20, VSA20A |
20000 | |
Cable charging current (amps) |
2 | |
Magnetizing current (amps) |
VSA12,VSA12B VSA16, VSA20 |
28 |
VSA20A |
42 | |
Three-second current, symmetric (amps) |
VSA12, VSA12B |
12000 |
VSA16 |
16000 | |
VSA20, VSA20A |
20000 | |
Momentary current, asymmetric (amps) |
VSA12, VSA12B |
20000 |
VSA16 |
25600 | |
VSA20, VSA20A |
32000 | |
Capacitive switching, general purpose, isolated bank (amps) |
250 |
Percent of maximum circuit interrupting rating |
Maximum X/R ratio |
Number of unit operations |
15-20 | 4 | 88 |
45-55 | 8 | 112 |
90-100 | 16 | 32 |
Total 232 |
Trip solenoid | Operating voltage, Vdc | 24 | |
Peak current, A | 12.2 | ||
Actuation time, cycles | 1.25 | ||
Close solenoid | Operating voltage, Vdc | 24 | |
Peak current, A | 15.5 | ||
Actuation time, cycles | 1.5 | ||
Standard |
Accessory |
||
Spring charging motor | Operating voltage, Vac |
240 | 120 |
Voltage range, Vac |
160-257 | 90-127 | |
Maximum current, RMS, A |
14 | 18 | |
Steady state current, A |
4.1 | 9 | |
Motor running time, cycles |
40 | 40 | |
Sensing current transformers | VSA12, VSA16 |
1000:1 | |
VSA20VSA20A |
2000:1 | ||
Maximum arcing time, cycles |
1.0 | ||
Interrupting time, cycles |
2.5 |
Operating temperature, °C |
Minimum |
-30 |
|
Maximum |
VAS12, VSA12B, VSA16, VSA20 | +50 |
|
VSA20A | +40 | ||
Closing mechanism | Spring-operated | ||
Opening mechanism |
Spring-operated |
||
Contact gap, mm (in) | 11 (7/16) |
||
Close contact travel time, cycles |
.5 | ||
Open contact travel time, cycles |
.5 | ||
Allowable contact erosion, mm (in) |
3 (.125) | ||
Opening time, 24 Vdc solenoid, signal to contact part, msec |
25 | ||
Closing time, 24 Vdc solenoid, signal to contact make, msec |
32 | ||
Mechanical life Open-Close, no load, operations |
2500 |
Volts |
Inductive ac (amps) |
Non-inductive ac (amps) |
Inductive dc (amps) |
Non-inductive dc (amps) |
24 | – |
– |
15.0 | 20.0 |
48 | – |
– |
7.5 | 10.0 |
120 | 60 | 80 | – |
– |
125 | – |
– |
1.5 | 2.0 |
240 | 30 | 60 | – |
– |
250 | – |
– |
0.45 | 0.5 |
Visit this page for information on earlier models.