Obstruction lighting

ALTR X4 alternating light control transfer relay for hazardous areas

The Crouse-Hinds series ALTR-X4 is an economical solution for hazardous area applications where the obstruction lights are difficult and/or expensive to service, such as towers or stacks that have obstruction lights that are inaccessible through normal methods.

Utilizing a Class I, Division 2 enclosure, the ALTR-X4 alternates between each light in a double obstruction light assembly each time the tower lights are energized by the photocontrol.  This ensures equal usage of the lights over the life of the lamps. In the event one of the lights fails, the ALTR-X4 automatically energizes the operational light and provides an output for remote alarm monitoring.

The ALTR-X4 provides maximum life on both lights and essentially doubles the time between service calls.

Need help with configurations and regulations? We can help.

The Eaton team has over 90 years of combined harsh and hazardous area lighting and design experience to help solve your obstruction lighting challenges. Our Eaton lighting experts treat every application as a unique situation. In many cases, we are able to offer several options, based on factors including FAA/FCC and ICAO requirements, special environmental or zoning issues, and characteristics of the structure to be lighted. We excel in custom design and determining the “best fit” approach to your unique obstruction lighting application.

Certifications and compliances

  • Class I, Division 2, Groups B, C, D
  • NEMA 4

Design features

  • Alternating feature doubles lamp life
  • Custom drill and tap available upon request
  • Designed for outdoor mounting
  • Can be installed at the base of the LED light fixture or at ground level at the base of the structure
  • NPT conduit entries located on the top and bottom of enclosure
  • AC input: 120 VAC or 230 VAC, 50/60 Hz
Specifications

Ordering information

Catalog number Product description
70026-RTO-X4 120 VAC, transfer relay assembly for L-810 dual fixtures –Primary light and backup light roles set permanantly
70226-RTO-X4 120 VAC, transfer relay assembly for L-810 dual fixtures –Primary light and backup light roles set permanantly
70029-RTO-X4 120 VAC, alternating transfer relay assembly for dual fixtures – Primary light and backup light switch roles at each photocelltransition (typically 12 hours) 
70229-RTO-X4 240 VAC, alternating transfer relay assembly for dual fixtures –Primary light and backup light switch roles at each photocelltransition (typically 12 hours) 