Reimagined ground fault trip protection

The innovative redesign of Eaton’s BR two-pole ground fault circuit breaker significantly reduces ground fault tripping while enabling faster troubleshooting and resolution of issues.

New digital GFCI protection advances safety, reliability for residential and light commercial 240 V applications

Eaton’s BR two-pole ground fault circuit breaker redesign introduces a new approach to ground fault protection that greatly decreases tripping events, making it ideal for variable frequency drives (VFDs) and 240 V equipment. The microprocessor-based design makes decisions about leakage and responds appropriately in milliseconds, providing time for the circuit breaker to disregard transient conditions that could lead to unwanted tripping. In addition, troubleshooting is faster and more accurate with the addition of 12 new trip code notifications.

Eaton 2P Breaker
Iconos

Digital ground fault protection optimizes breaker response for 240 V equipment.

Iconos

Diagnose and resolve tripping events much faster through 12 new trip codes that provide specific indicators for tripping sources.

Iconos

New manufacturing processes increase capacity, so stock is available when you need it for your next job.

Diagnose and resolve tripping events faster

Eaton's BR two-pole ground fault circuit breaker relies on 12 new trip code notifications to improve the accuracy of trip diagnosis, aid troubleshooting efforts during maintenance and enable prompt resolution of issues. With specific indicators and improved diagnostic capabilities, the codes enable the pinpointing of complex occurrences and overloads for quick identification of error conditions including hardware and microprocessor malfunctions, as well as power quality issues such as over-voltage, over-current and ground fault issues.

Eaton 2P Breaker

Reduce costs with more efficient bill of materials

Eaton’s BR two-pole ground fault circuit breaker boasts an improved series rating, offering additional combinations up to 60 A. And with higher interrupts and #3AWG lugs that reduce wiring costs, the circuit breaker allows for more cost-efficient project bills of material, most notably for multi-family jobs.

gfci afci requirements family

Ensure NEC code compliance for GFCI protection

The BR two-pole ground fault circuit breaker is an ideal solution to satisfy ongoing and expanding NEC requirements for ground-fault circuit-interrupter (GFCI) protection, including the increase of amp protection ratings across all receptacle outlets, both indoor and outdoor, wherever GFCI protection is required. In an effort to reduce the dangers associated with electrical hazard and shock, the NEC continues to broaden its scope of branch circuit requirements, with recent additions now mandating GFCIs in kitchens, laundry areas, basements, garages, outdoor outlets, and any areas with sinks or other damp or wet locations.

eaton-metallic-finish-gfci-300fb.jpg

Eaton’s latest innovation: the redesigned BR two-pole ground fault circuit breaker

Eaton's BR two-pole ground fault circuit breaker is quick, clean and easy to install for plug-on neutral equipment up to 30 A. See how our 2P breaker smartly navigates brief disturbances to prevent unwarranted tripping and explore the 12 new trip code notifications that bring speed and accuracy to your problem-solving process.

Make installation a breeze

Eaton's BR two-pole ground fault circuit breaker is quick, clean and easy to install for plug-on neutral equipment up to 30 A. With Eaton’s “Rock ‘N’ Lock” feature, the circuit breaker clip easily rocks onto the redesigned in-board neutral, providing a safe and secure connection while also affording maximum gutter space within the load center and operating at cooler temperatures.