900VA 480W Standby UPS - 12 NEMA 5-15R Outlets, 120V, 50/60 Hz, 5-15P Plug, ENERGY STAR, Desktop/Wall
Product Name |
Eaton Tripp Lite series UPS
|
Catalog Number |
INTERNET900U
|
UPC |
037332211095
|
Product Length/Depth |
14.92 in
|
Product Height |
7.83 in
|
Product Width |
5.98 in
|
Product Weight |
8.1 lb
|
Compliances |
RoHS
ENERGY STAR certified FCC Class B |
Certifications |
UL 1778
CSA certified CSA Std. C22.2 NOM RETIE |
Global Catalog |
INTERNET900U
|
Topology |
Standby
|
Form factor |
Desktop
|
Package contents |
|
Input nominal voltage |
120 VAC
|
Nominal frequency |
50/60 Hz
|
Input frequency range |
50/60 Hz
|
Receptacle |
5-15R
|
Output nominal voltage |
110 / 120V
|
Electric current - max |
|
Battery replacement |
IMPORTANT BATTERY REPLACEMENT INFORMATION > If your INTERNET900U has no battery access door, please contact a local electronics repair technician to source and install a matching replacement battery; If your INTERNET900U UPS does have a battery replacement door, please order Tripp Lite RBC51 (quantity 1) replacement battery
|
Runtime at half load |
7.8 min
|
Relative humidity |
0-95% non-condensing
|
Output Receptacles |
5-15R
|
Product Highlights |
900VA ultra-compact 120V standby UPS
Maintains AC output during power failures 6 UPS battery supported outlets, 6 surge-only outlets ENERGY STAR Version 2.0 qualified USB, TEL/DSL protection, Wall mountable, 99% efficient NEMA 5-15P input plug and 12 NEMA 5-15R outlets Protects equipment against blackouts, brownouts, overvoltages, surges and line noise Keeps AC power running during blackouts to allow time for file saves and safe shutdown 12 NEMA 5-15R outlets power and protect PC, home theater or digital signage equipment Home-friendly alarm remains silent in backup mode, sounding only when imperative ENERGY STAR-certified to save electricity, lower costs, and protect the environment |
PowerAlert Software |
For local monitoring via the UPS’s built-in USB port, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
Nominal Output Voltage |
110V
115V 120V |
Network Management Cards Details |
Network management not supported
|
Output power factor |
0.53
|
Phase (input) |
Single-phase
|
Runtime at full load |
1.7 min. (480W)
|
Communication interface |
USB (HID enabled)
USB interface cable included |
Battery Access |
Battery access door
|
Dc Voltage |
12
|
Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
Communications Cable |
USB interface cable included
|
Input Circuit Breakers |
10A
|
High Voltage Transfer to Battery Power |
145
|
Low Voltage Transfer to Battery Power |
95
|
Application |
|
Switch configuration |
Switch controls power off/on status
|
AC suppression joule rating |
316
|
Housing material |
ABS
|
Output AC waveform (AC mode) |
Pure sine wave
|
Output AC waveform (battery mode) |
PWM sine wave
|
Output Capacity (kVA) |
.9
|
Output Capacity (kW) |
.48
|
Output Capacity (VA) |
900
|
Output Capacity Details |
7.5A @ 120V. 110%±10%,GOES TO FAULT AFTER 5MIN; 120%±10%,GOES TO FAULT IMMEDIATELY 110%±10%,SHUTS DOWN IN 5 SEC; 120%±10%, SHUTS DOWN IMMEDIATELY
|
Operating Elevation |
Up to 3000m
|
Primary UPS Depth (mm) |
310
|
Primary UPS Height (mm) |
85
|
Primary UPS Width (mm) |
130
|
AC Suppression Response Time |
Instantaneous
|
Audible Alarms |
UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions
|
Battery Start Capability |
Cold-start operation supported
|
Battery Replacement Description |
Replaceable internal battery. Contact customer support for assistance.
|
LED Indicators |
Set of 3 status LEDs indicate operating mode, low-battery, overload, replace-battery and fault conditions
|
Frequency Rating Details |
Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
|
Output Voltage Regulation (Line Mode) |
120V (±20%)
|
Output Voltage Regulation(Battery Mode) |
120V (±10%)
|
Rechargeable Battery |
8 hours (10% to 90%)
|
Recommended Electrical Service |
15A 120V
|
Storage Temperature |
5° to 113°F (-15° to 45°C )
|
Nominal Voltage Details |
120V sinusoidal in line mode and 120V PWM in battery mode
|
Voltage Regulation Description |
Input voltage range of 95 to 145
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Maximum Input Amps |
10
|
UPS Input Cord Length (m) |
1.5
|
UPS Power Module Dimensions |
3.35 x 5.12 x 12.2
|
Power Mode Transfer Time |
6 milliseconds typical (10 milliseconds max)
|
Connected Equipment Insurance |
$100,000 Ultimate Lifetime Insurance
|
EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
UPS Input Connection Type |
5-15P
|
Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
|
UPS Dataline Suppression |
1 line TEL/DSL or Ethernet
|
UPS Output Receptacles |
6 UPS outlets, 6 surge-only outlets
|
High Availability UPS Features |
Surge/noise protection
|