500VA 360W Line-Interactive UPS with 6 Outlets - AVR, 120V, 50/60 Hz, LCD, USB, Tower
| Product Name |
Eaton Tripp Lite series UPS
|
| Catalog Number |
OMNISMART500TU
|
| UPC |
037332221544
|
| Product Length/Depth |
16.3 in
|
| Product Height |
9.8 in
|
| Product Width |
7.2 in
|
| Product Weight |
14.3 lb
|
| Compliances |
RoHS
FCC Class A |
| Certifications |
UL 1778
NOM CSA certified |
| Topology |
Line-interactive
|
| Form factor |
Tower
|
| Package contents |
|
| Input nominal voltage |
120 VAC
|
| Nominal frequency |
50/60 Hz
|
| Input frequency range |
50/60 Hz
|
| Receptacle |
5-15R
|
| Output nominal voltage |
110 / 120V
|
| Electric current - max |
|
| Battery replacement |
RBC51
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Runtime at half load |
10 min
|
| Relative humidity |
Up to 90% non-condensing
|
| Front Panel LCD Display |
LCD touchscreen reports input and output voltage, load percentage and battery charge level; Also reports overload and critical fault code screens (see manual)
|
| Output Receptacles |
5-15R
|
| Product Highlights |
High >95% efficiency with low BTU ratings saves power and lowers your energy costs
AVR battery backup allows time to save files and safely shut down during blackouts 6 NEMA 5-15R outlets provide power to PC, home theater or digital signage equipment Easy-to-read LCD touchscreen provides valuable voltage, load and battery data Protects equipment against blackouts, brownouts, overvoltages, surges and line noise High >95% efficiency with low BTU ratings saves power and lowers your energy costs |
| PowerAlert Software |
For local monitoring via the UPS’s built-in USB communications port, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
110V
115V 120V |
| Network Management Cards Details |
Network management not supported
|
| Output power factor |
0.72
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
3 min. (360W)
|
| Communication interface |
USB (HID enabled)
USB cable included |
| Battery Access |
Includes bottom panel battery access door
|
| Dc Voltage |
12
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB cable included
|
| Input Circuit Breakers |
7A
|
| Output Circuit Breakers |
6A
|
| High Voltage Transfer to Battery Power |
145
|
| Low Voltage Transfer to Battery Power |
89
|
| Undervoltage Correction |
Input voltages between 89 and 108 are boosted by 14%
|
| Application |
|
| Switch configuration |
Power switch enables UPS on / off control
|
| Hot Swap PDU Options |
PDUB15 (2U / 8 5-15R outlets)
|
| AC suppression joule rating |
316
|
| Housing material |
ABS
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
PWM sine wave
|
| Output Capacity (kVA) |
0.5
|
| Output Capacity (kW) |
0.36
|
| Output Capacity (VA) |
500
|
| Output Capacity Details |
4.2A @ 120V. (LINE MODE) 110%+/- 10% @ 5 minutes; (BATTERY MODE) 110% +/- 10% @ 5 seconds
|
| Primary UPS Depth (mm) |
345
|
| Primary UPS Height (mm) |
160
|
| Primary UPS Width (mm) |
122
|
| AC Suppression Response Time |
Instantaneous
|
| Audible Alarms |
Alarm reports low-battery, fault, overload and replace battery conditions; Alarm remains silent during battery mode operation until low-battery status occurs
|
| Battery Start Capability |
Cold-start operation supported
|
| Battery Replacement Description |
Replaceable internal battery (see manual)
|
| Frequency Rating Details |
Automatic frequency selection. Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
|
| Output Voltage Regulation (Line Mode) |
-12%, +9%
|
| Output Voltage Regulation(Battery Mode) |
±5%
|
| Overvoltage Correction |
Input voltages between 129 and 145 are reduced by 15%
|
| Rechargeable Battery |
8 hours from 10% to 90%
|
| Recommended Electrical Service |
15A 120V
|
| Storage Temperature |
5° to 113°F (-15° to 45°C )
|
| Nominal Voltage Details |
120V sinusoidal in line mode and 120V PWM in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 145
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
6
|
| UPS Input Cord Length (m) |
1.5
|
| UPS Power Module Dimensions |
6.3 x 4.8 x 13.6
|
| Power Mode Transfer Time |
6 milliseconds
|
| Connected Equipment Insurance |
$100,000 Ultimate Lifetime Insurance
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P
|
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
|
| UPS Dataline Suppression |
1 line TEL/DSL or Ethernet
|
| UPS Output Receptacles |
4 UPS outlets, 2 surge-only outlets
|
| High Availability UPS Features |
Automatic voltage regulation (AVR)
Surge/noise protection |
Support from Eaton