Surge protection

MTL FS32 fieldbus trunk and spur surge protection

The Crouse-Hinds series MTL FS32 family of surge protection devices prevent surges and transient over-voltages conducted along the Trunk or Spurs of fieldbus systems from damaging the associated electronics such as power supplies, device couplers, fieldbus barriers, terminators, and the bus control equipment. This space saving design helps to reduce the size of junction boxes and ease installation. In operation, the FS32 does not adversely affect the performance or operation of the fieldbus or connected equipment. It allows signals to pass with little attenuation while diverting surge currents safely to earth (ground) and clamping output voltages to safe levels. 

Designed to fit our latest fieldbus products, the FS32 surge protection devices can be fitted to our 9180 range of fieldbus power supplies, F300 and F200-IS range of Megablock device couplers and the intrinsically safe spurs of our fieldbus barrier wiring hubs. 

For applications requiring Ex eb certification, the FS32-XE provides surge protection for trunk and /or spur connections on a F200-XE MTL Megablock device coupler as well as trunk surge protection on on a 937x-FB3 MTL compact fieldbus barrier. These fieldbus components must be installed in an Ex e certified field enclosure for mounting in an IEC Zone 1 hazardous area.

Safety
Protects spurs on MTL 937x-FB range fieldbus
Safety
Meets requirements of IEC61158-2:2004
Performance
20kA maximum surge current per line

Certifications and compliances

ATEX Directive 2014/34/EU:

  • Ex ia IIB T3 Ga
  • Ex ia IIC T4 Ga (-40°C<Ta<+75°C) see schedule 
  • Ex ec IIC T4 Gc -40°C≤Ta≤+70°C

IECEx:

  • Ex ia IIB T3 Ga
  • Ex ia IIC T4 Ga (-40°C<Ta<+70°C) see schedule
  • Ex ec IIC T4 Gc -40°C≤Ta≤+70°C

Marine (Lloyds Register):

  • Test Specification No. 1, 2002 - Environmental Category ENV3

Ambient temperature limits:

  • Working: -40°C to +75°C (-40°F to +167°F )
  • Storage: -40°C to +80°C  (-40°F to +176°F)

FS32-XE Zone 1 devices:

  • ATEX Directive 2014/34/EU: 
  • Ex eb mb IIC (-40°C < Ta <+80°C)

IECEx:

  • Ex eb mb IIC (-40°C < Ta <+80°C)

Design features

FS32:

  • Protects intrinsically safe spurs on MTL 937x-FB range fieldbus
  • 20kA maximum surge current per line
  • Plug connectors for quick and easy connection or rewiring
  • Meets the requirements of IEC61158-2:2004
  • Can be used on MTL Megablocks or other fieldbus equipment
  • 10 year product warranty

FS32-XE:

  • Protects Zone 1 trunk on 937x-FB3 MTL compact fieldbus barrier
  • 20kA Total surge current
  • Plug connectors for quick and easy connection or rewiring
  • Compatible to Foundation™ fieldbus requirements of IEC61158-2:2014 and IEC6143-21
  • Protects trunk and spurs of F200-XE Megablock wiring hubs
  • 10 year product warranty